Hospital and Medical Emergency Baby Infant Incubator with High Quality

Customized: Non-Customized
Certification: CE, ISO13485
Scale: Medium
Type: Infant Incubator
Transport Package: Carton
Specification: Air Mode, Baby Mode
Diamond Member Since 2016

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
CY-2018001
Trademark
CIYE
Origin
China
HS Code
9018
Production Capacity
100 Sets Per Month

Product Description

Product Description
STANDARD COMPOSITION:
Servo Control Mode: Air temp;
Instant Parameter Displaying: Set temp, air temp, heat power rate;
Audible & Visual Alarms: Power failure, sensor failure, higher/lower temp, air temperature override, fan failure;
Power failure reset memory and self-test function;
Hood with dual slope: 4 hand-ports

SPECIFICATION
POWER

Model H-800-1E: 110 / 120 V ac, 50Hz / 60Hz
Model H-800-2E: 220 / 240 V ac, 50Hz / 60Hz
Power Input: ≤ 400VA
Refer to IEC60601-1, this equipment belongs to ClassI, Type BF Its operation is continuous
ALARM
Power Alarm
Power Failure: Activates if primary power to the Incubator fails or the power wire is accidentally disconnected from the wall receptacle
Fan Alarm
Fan Failure: Activates if Fan motor malfunctions
Sensor Alarm
Air Sensor Failure: Air Sensor malfunction, refer unit to service
Deviation Alarm
High Air Temperature: Activated if displayed Air Temperature is 15° C above set point
Low Air Temperature: Activated if displayed Air Temperature is 25° C below set point
Over Temperature Alarm
Over Air Temperature: Activated when displayed Air Temperature was approach 38° C in Air Mode
System Alarm
System Failure: Activated if Temperature Control System malfunctions

TEMPERATURE CONTROL RANGE AND CORRELATIVE SPECIFICATIONS
Air Temperature: 20° C~37° C
Temperature Rise Time: ≤ 30min
Temperature Variability: ± 0.5° C
Temperature Uniformity: ≤ 1° C
ENVIRONMENT REQUIREMENT
Environment Temperature
Operation Temperature Range: +20° C ~ +30° C
Store Temperature Range: -40° C ~ +55° C
Environment Humidity
Operation Humidity Range: 30%~75%
Store Humidity Range: 10%~100%
Atmospheric Pressure Range: 700hPa~1060hPa
OTHER SPECIFICATION
Noise Level Within Hood Environment: ≤ 55dB(Environment noise below 45dB)
Carbon Dioxide (CO2) Level within the Hood: Less than 05% when a mixture of CO2 in air is delivered at 750ml/min at a point 10cm above the center of the mattress
Air Velocity Over Mattress: Less than 035m/s
Infant Bed Max Load: 10kg
Transfusion Shelf Max Load: 2kg
FACTORY DEFAULT SETTINGS
Temperature Control Mode Air Temperature Mode
Air Set Temperature: 32° C
Temperature Units: ° C

NOTE: Open Access Panel or Access Door or the use of supplies or other equipment within the Incubator, which can alter the air flow pattern, may effect temperature uniformity, temperature variability, the correlation of the Incubator temperature reading to center mattress temperature and skin temperature